Frequently Asked Questions: Industrial

Can I locate my compressor outdoors without problems?

The primary issues are winter freezing conditions, and rain water effects on the electrical components. Many Sullair compressors can be ordered with options that address most of these concerns. Check with the factory or the local distributor for exact requirements.
[back to top]

Do all Supervisor controls have auto restart?

Yes. Can we get a DS with Y-delta start? No. Standard motors do not produce enough torque.
[back to top]

If I put a bigger motor on my compressor, how much more air will I get?

None. The Sullair rotary screw is positive displacement compressor, and air flow is dependant on speed. A higher horsepower motor can help if additional pressure is required.
[back to top]

Is Supervisor available on the 10 Series?

No. The current electrical box is too small to handle the Supervisor panel.
[back to top]

What is the difference between ACFM and SCFM?

Nothing, if your site conditions exactly match the "standard conditions". "Standard" ambient conditions as defined by CAGI (the Compressed Air and Gas Institute) are 14.7 psig atmospheric pressure, 68 degrees Fahrenheit, and 0% relative humidity.
[back to top]

What is the NEMA rating for the standard electrical enclosures in Sullair compressors?

NEMA1 on the 10 series and ES6 and NEMA12 on the balance of the compressor line. Other NEMA rated enclosures are available as options.
[back to top]

What is the standard compressor fluid fill?

Sullube 32 is standard on all packages and 24KT on all ten year warranty packages. Only exception is the DS family that uses Mobil DTE light.